35kV Single-Core Cold Shrink Indoor Termination Kit
- 35kV single-core cold shrink termination kit for XLPE-insulated power cables in indoor electrical installations.
- RIKI’s 35kV accessory range covers 21/35kV and 26/35kV cable voltage designations, subject to confirmation of the selected configuration.
- Four conductor-size selections: 35โ120, 150โ240, 300โ500 and 630 mmยฒ.
- Intended for preparing individual cable ends for connections to suitable indoor medium-voltage equipment.
- Termination selection requires the cable datasheet, insulation dimensions and equipment connection details; cold shrink contraction does not require applied heat.
From Cable Schedule to Equipment Connection: Specifying a 35kV Indoor Termination
A cable schedule may identify a 35kV XLPE feeder and its conductor cross-section, yet still leave the termination supplier without enough information to select the complete cable-end arrangement. The missing details are often found in separate documents: the cable datasheet, the equipment terminal drawing and the project’s installation requirements.
RIKI’s 35kV single-core indoor cold shrink termination range is catalogued for 21/35kV and 26/35kV XLPE-insulated power cables. It offers four conductor-size selections, from 35โ120 mmยฒ through a separate 630 mmยฒ option. The product prepares one cable end for connection to suitable indoor electrical equipment, rather than joining two cable lengths together.
What the Cable Schedule Can Tell You
The conductor cross-section identifies the initial size group. The complete cable designation establishes the applicable voltage class and insulation system. However, these entries do not fully describe the cable’s insulation outside diameter, screen construction or the dimensions at the prepared end.
Those measurements matter because the termination components must fit the actual XLPE cable construction. In particular, the insulation dimensions and the cable manufacturer’s preparation requirements should be checked before the selected size is approved. The published size table is a starting point for selection, not a universal compatibility certificate.
What the Equipment Drawing Adds
A termination ends at an electrical connection. The equipment drawing should identify the terminal interface, lug connection arrangement, cable entry position and available installation space. These details establish whether the prepared cable can reach its connection point without violating cable bending limits or the clearances required by the equipment design.
The indoor designation describes the intended application environment of this product range. It does not establish suitability for every switchgear compartment, enclosure arrangement or equipment interface. Those conditions must be checked against the completed installation.
What Should Be Settled Before the Purchase Order
For a single-core 35kV termination enquiry, the two most useful supporting documents are the actual cable datasheet and the equipment connection drawing. Together, they allow the buyer and supplier to review the conductor material and size, insulation diameter, screen arrangement, cable routing and terminal requirements.
Kit quantity also matters. When a three-phase circuit uses three separate single-core cables, each cable end requiring termination must be accounted for individually. The project bill of materials should distinguish the number of complete terminations from the number of cable circuits.
Finally, buyers should confirm the supply package and any project-specific test documentation before approval. A photograph of the termination components cannot establish lug inclusion, exact cable fit, certification scope or acceptance under a particular project specification.
35kV Indoor Termination Product Data and Four Conductor-Size Selections
| Product Name | 35kV Single-Core Cold Shrink Indoor Termination Kit |
|---|---|
| Brand | RIKI |
| Manufacturer | Zhejiang Ruikai Electric |
| Product Category | Cold Shrink Cable Accessories |
| Product Type | Medium Voltage Indoor Cable Termination |
| Voltage Class | 35kV |
| Catalog Cable Voltage Designations | 21/35kV and 26/35kV |
| Cable Configuration | Single-Core |
| Applicable Cable Insulation | XLPE |
| Installation Environment | Indoor |
| Termination Technology | Cold Shrink |
| External Heating for Component Contraction | Not Required |
| Available Conductor Cross-Sections | 35โ630 mmยฒ across four size selections |
| SKU and Applicable Cable Section | |
| SKU: NLS-35/1.1 | 35โ120 mmยฒ |
| SKU: NLS-35/1.2 | 150โ240 mmยฒ |
| SKU: NLS-35/1.3 | 300โ500 mmยฒ |
| SKU: NLS-35/1.4 | 630 mmยฒ |
The conductor-size and voltage selections follow RIKI’s published 35kV cable accessory catalog. Final termination compatibility depends on the actual cable insulation dimensions, screen construction and equipment connection requirements. The table does not establish individual SKU certification or compatibility with every cable manufacturer.
Frequently Asked Questions (FAQ)
What documents should accompany a 35kV indoor termination enquiry?
The cable datasheet and equipment connection drawing are the most useful starting documents. The cable information should identify the complete voltage designation, conductor material and size, insulation diameter and metallic-screen construction. The equipment drawing helps establish the terminal arrangement and available space. Additional project requirements, including specified test documentation, should be submitted before final kit approval.
Does an indoor termination automatically fit any metal-enclosed switchgear?
No. The indoor product designation does not establish compatibility with every switchgear compartment. Cable entry direction, equipment terminal dimensions, required electrical clearances and available working space all affect installation. The cable’s bending limits and the termination’s approved preparation dimensions must also be respected. Review the actual equipment drawings before selecting the final arrangement.
How should termination quantities be calculated for a circuit using separate single-core cables?
Count the cable ends that require termination, rather than counting the number of three-phase circuits alone. Each single-core cable end needs its own suitable termination arrangement. The total order quantity therefore depends on the number of phase cables, connection points and cable ends being prepared. Confirm whether the supplied package is priced and packed per individual termination.
Can different conductor sizes be grouped under one purchase-order item?
They belong to the same product family but should be identified by their individual ordering codes and quantities. The published range has four distinct size selections, and one kit size should not be substituted for another without a compatibility review. A project purchasing schedule should separate the required conductor ranges and identify any different cable constructions associated with them.
Indoor 35kV Cable End Connections and Procurement Applications
Indoor Substation Feeder Ends
Preparing single-core XLPE cable ends for suitable indoor medium-voltage equipment connections where cable and terminal compatibility are confirmed.
Substation ยท Cable Ends
Separate Single-Core Feeder Runs
Planning individual cable-end terminations for three-phase feeder circuits built from separate single-core cables.
Individual Cores ยท Kit Quantity
Large-Section Cable Connections
Equipment termination planning for larger conductors, including the separate 630 mmยฒ selection in the published 35kV range.
Large Conductors ยท XLPE
Project Material Schedules
Organizing termination orders by voltage designation, conductor-size group, cable specification and required number of cable ends.
Engineering RFQ ยท B2B Supply