Skip image slider
Red 15kV 200A bushing extender holder with ribbed insulating body, stepped upper housing and visible metal end fitting
Red 15kV 200A bushing extender holder with ribbed insulating body, stepped upper housing and visible metal end fitting

15kV 200A Bushing Extender Holder

The RIKI 15kV 200A bushing extender holder is a separable cable connector accessory for transformer and switchgear connection assemblies. Its ribbed insulating body incorporates a rain-shed profile, and the catalog identifies mating arrangements involving bushing joints, rotatable feedthru inserts and surge arresters. Buyers should verify the equipment interface, physical dimensions and required matching components before selecting it for a new installation or replacement.

Products Categories
Get A Free Quote
Request a Quote

An Extended Bushing Connection Has Two Interfaces to Get Right

An extended bushing holder may be selected because of the equipment’s connection arrangement, but the word “extended” does not tell a buyer which mating components will fit. Two connection points need attention: the apparatus-side mounting interface and the accessory fitted to the exposed end.

RIKI identifies this 15kV, 200A model as a bushing extender holder for transformers, outdoor cable distribution cabinets and switchgear. The catalog also describes connections involving bushing joints, rotatable feedthru inserts or surge arresters. Those are application possibilities, not confirmation that every accessory with a 200A marking can be fitted directly.

The Mating Interface Determines Compatibility

A 200A current rating identifies an electrical class. It does not fully describe the connector profile, mounting dimensions or attachment method.

When replacing an existing holder, record the original component model and examine the equipment connection drawing. The mating accessory also needs to be identified. A bushing insert, a bushing well and an extended holder are related components, but they perform different functions within a separable connector assembly.

For a new installation, the equipment supplier should confirm the required interface geometry and connection arrangement before the accessory order is approved. This is more useful than choosing a part solely because the voltage and current markings match.

Why the Insulating Body Has Ribs

The red product photograph shows a series of closely spaced external ribs below the main body. RIKI’s catalog describes a special rain-shed structure intended to increase the surface creepage path.

This geometry is relevant to equipment installations where the insulating surface may be exposed to moisture or contamination. Yet the visible ribs do not establish a numerical creepage distance, pollution class or specific outdoor qualification. These values should come from the applicable product drawing and test documentation.

The color of the insulating body is not an electrical specification. The supplied red product image and the black catalog illustration should be associated with the confirmed model, while any color-specific material or test requirements must be checked separately.

Do Not Confuse a 200A Holder with a 600A Conversion Accessory

RIKI’s accessory catalog contains another product described as a 600A bushing extender. That product has a separate model designation and a different stated purpose involving a 600A-to-200A connection arrangement.

The present 15kV 200A extender holder should not be described as a universal 600A-to-200A adapter. Its intended connection and electrical rating must be established from the actual holder model and the approved mating components.

This distinction matters when a buyer submits a photograph of an existing transformer bushing but does not identify the interface. A voltage rating and an external shape are not sufficient to decide whether a conversion component or an extended 200A holder is required.

What to Check on a Replacement Order

The existing connection location can impose dimensional restrictions. Available projection from the equipment wall, nearby accessories and access to the mating connection may affect whether the replacement will fit.

Ask for the apparatus drawing, original part identification and details of the intended mating component. If this is a replacement order, photographs of the existing installation can help identify the arrangement, but they do not replace a dimensional drawing.

Confirm the connection interfaces, mounting dimensions and any required accessories before ordering. The current catalog does not publish a verified extension length or a complete list of compatible mating models for this specific holder.

15kV Bushing Extender Holder — Electrical Ratings and Interface Details

Product Name 15kV 200A Bushing Extender Holder
Product Model HY JCTGZ-15/200
Brand RIKI
Manufacturer Zhejiang Ruikai Electric
Product Type Bushing Extender Holder / Extended Bushing Well
Rated Voltage 15kV
Rated Current 200A
Typical Equipment Transformers, Outdoor Cable Distribution Cabinets and Switchgear
External Insulation Profile Ribbed Body with Rain-Shed Structure
Product Image Red Insulating Body with Metal End Fitting
Catalog-Described Associated Components Bushing Joint, Rotatable Feedthru Insert and Surge Arrester; Actual Mating Compatibility Must Be Confirmed
Connection Interface Equipment-Specific Mating Geometry; Verify Against Approved Drawings
Installation Configuration Extended Apparatus Bushing Connection Arrangement
Dimension and Extension Length Require Product-Specific Drawing
Applicable Interface Standard Check Project IEEE 386 Requirements and Model-Specific Conformity Documents

The 15kV and 200A ratings and application description follow the published RIKI catalog. Interface dimensions, mating-component compatibility, exact creepage distance, loadbreak switching capability and IEEE 386 conformity are not established by the catalog information provided here. These details require confirmation for the selected model and equipment assembly.

Frequently Asked Questions (FAQ)

Is a bushing well extender the same as a loadbreak bushing insert?

No. A bushing well extender holder and a loadbreak bushing insert have different functions in a separable connector assembly. A loadbreak bushing insert is designed to mate with a suitable bushing well and compatible elbow connector. The extender holder is a separate apparatus accessory, so its mounting arrangement and mating interfaces must be checked independently. Matching 15kV and 200A ratings do not establish direct interchangeability.

Can this holder be used with a rotatable feedthru insert or surge arrester?

The RIKI catalog mentions rotatable feedthru inserts and surge arresters among the associated connection arrangements. However, the exact mating interface, voltage rating and accessory configuration must be verified for the selected combination. The catalog description does not establish compatibility with every 200A feedthru insert or surge arrester available on the market.

Can this 200A holder convert a 600A bushing into a 200A connection?

Do not use this model as a 600A-to-200A conversion accessory without specific technical confirmation. RIKI lists a separate 600A bushing extender product for conversion applications. This model is identified as a 15kV 200A bushing extender holder. The equipment’s existing bushing class and required connection interface should determine which accessory is selected.

Does the rain-shed structure prove suitability for every outdoor installation?

No. The external ribs provide a longer surface insulation path, as described in the product catalog, but the photograph does not establish a specific creepage distance or pollution rating. Outdoor suitability depends on the complete insulating assembly, environmental conditions and applicable qualification requirements. The required technical evidence should be reviewed for the intended installation.

Where an Extended 200A Apparatus Connection May Be Required

Transformer

Transformer 200A Connection Assemblies

Extended bushing arrangements for suitable transformer outgoing connections, with the apparatus mounting profile and mating accessory verified before installation.

Distribution Cabinet

Outdoor Cable Distribution Cabinets

Equipment connection layouts requiring an extended insulated holder, subject to the cabinet's available clearance, environmental conditions and approved interface geometry.

Switchgear

Switchgear Accessory Connections

200A-rated connection assemblies where the selected bushing holder must coordinate with compatible feedthru or other associated accessories.

Replacement

Existing Bushing Holder Replacement

Replacement procurement where the original holder model, physical mounting dimensions and receiving accessory need to be matched rather than selected by appearance alone.

Related tubing & BarBus Insulation

Scroll to Top

Get A Free Quote Now !

Request a Quote
Partner with Major Disposal. We offer competitive factory-direct pricing and dedicated support for your large-scale projects.
about us